Fluke : thermal imagers: Ti25, Ti10, TiR1, TiR
Fluke new gun-type thermal imagers for different applications: service, industry, building diagnostics etc. . All cameras includes IR-Fusion option, which allows to make from the object IR & digital photo, For Ti25 & TiR1 there is also voice memo recording function included
Technical data :
• temperature range ( thermal sensitivity / accuracy / min. span( auto/manual )) :
Ti10 : -20..+250°C ( sensitivity: 0,2°C / accuracy : +-5°C / min. span:10°C / 5°C
Ti25 : -20..+350°C ( sensitivity: 0,1°C / accuracy : +-2°C / min. span: 5°C / 2,5°C
TiR : -20..+100°C ( sensitivity: 0,1°C / accuracy : +-5°C / min. span: 5°C / 2,5°C
TiR1 : -20..+100°C ( sensitivity: 0,07°C / accuracy : +-2°C / min. span: 5°C / 2,5°C
• field of view( FOV): 23° (H) x 17° ( V ) ; min. focus: 15cm ( IR) / 46cm ( visual image)
• detector: 160 x 120 FPA ; digital camera : 640 x 480 pxl. color
• camera modes : PIP( ; Ti25 & TiR1 - 3 levels ); full IR-picture
• on-screen emissivity correction : 0,1...1,0 ( Ti25, TiR1 )
• central point, warm-cold markers: Ti25, TiR1 / central point: TiR, Ti10
• LCD-screen: 9,1cm, VGA(640x480), color; 2 backlight levels
color palettes: ironbow, blue-red, high contrast, grey / Ti25 & TiR1 in addition: hot metal, amber
• data storage: 2GB SD-card ( up to 3000.bmp IR-pics & 1200.IS2 IR-fusion pics
• file formats: JPEG, BMP, GIF, PNG, TIFF, WMF, EXIF, EMF
• voice memo recording ( only Ti25, TiR1 )
• software: SmartView
• on-screen functions: Hi-Lo alarms, central point, date/time , level & span
Ti25,TiR1 in addition : cold-hot markers
• power: rech. battery ( lifetime : 3-4h); recharge time : ca' 2h / 230VAC adapter
• operating temperature: -10...+50°C; IP54
• more information: Ti25/Ti10, TiR/TiR1
Fluke : combined infrared- contact thermometers Fluke 566 & Fluke 568
New Fluke 566 & 568 models in infrared thermometer list.
Technical data :
• temperature range( resolution / accuracy ) :
Fluke 566 : -40..+650°C ( resolution : 0,2°C / accuracy : +-1°C
Fluke 566 : -40..+800°C ( resolution : 0,2°C / accuracy : +-1°C
• spectral response: 8...14 µm
• response time: less than 500ms
• emissivity: 0,1...1,0 ( samm: 0,01 );
internal material emissivity table
• contact-probe measuring range: -270...1372°C ( accuracy: +-1 °C )
• optics: 30:1 ( Fluke 566 ) ; 50:1 ( Fluke 568 )
• memory: 20 locations( Fluke 566 ) ; 99 locations( Fluke 568 )
• computer interface ( Fluke 568 ). USB 2.0, FlukeView Forms software
• Hi/Lo alarms, MIN/MAX/AVG/DIF-functions, backlight ( 2 levels)
• operating temperature: 0...+50°C
• power: 2 x AA batteries( lifetime: 12h ; without backlight & laser:100h )
• size/weight: 25,4 x 19,1 x 6,9cm / 0,965g
• includes: IR-thermometer, hard case, 2xAA batteries, K-type probe,
Fluke 568 in addition: FlukeView Forms software & USB-cable
• täiendav info : Fluke 566/568
• Ask for the price & information : sven@ronex.ee ; tel.+372 6556672
News archive
Fluke: New thermal imagers & infrared thermometers
15.01.2008
New Thermal imagers Fluke Ti10, Ti25, TiR, TiR1 and combined noncontact-contact thermometers Fluke 566 & Fluke 568.