CATALOG PRODUCTS
-
SWITCHING POWER SUPPLY - SINGLE OUTPUT - 600 W - 24 V
Product code:
HLG-600H-24A
Description:
Features:- universal AC input / full range (up to 305 VAC)
- built-in active PFC function
- no load power consumption <0.5W at remote OFF
- high efficiency up to 96%
- -40 °C - +70°C wide operating range
- protections: short-circuit / overload / overvoltage / overtemperature
- cooling by free air convection
- IP65 design for indoor or outdoor installations
- withstand 5G vibration test
- three in one dimming function
- suitable for dry / damp / wet locations
- 5 years warranty
- for professional use only
- This device must be installed by a qualified person.
- output:
- DC voltage: 24 V
- constant current region (Note.4): 12 V to 24 V
- rated current: 25 A
- rated power: 600 W
- ripple & noise (max.) (Note.2): 150 mVp-p
- voltage adj. range (Note.6): 20.4 to 25.2 V
- current adj. range:
- can be adjusted by internal potentiometer A type only
- 12.5 to 25 A
- voltage tolerance (Note.3): ± 1.0 %
- line regulation: ± 0.5 %
- load regulation (Note.8): ± 0.5 %
- setup, rise time (Note.9): 500 ms, 80 ms at full load 230 VAC / 115 VAC
- hold-up time (typ.): 15 ms at full load 230 VAC / 115 VAC
- input:
- voltage range: 90-305 VAC 127-431 VDC
- frequency range: 47 to 63 Hz
- power factor: PF >/= 0.98 / 115 VAC , PF >/= 0.95 / 230 VAC, PF >/= 0.93 / 277 VAC at full load
- total harmonic distortion: THD <20% when output loading >/=50% at 115VAC/230VAC input and output loading >/=75% at 277VAC input
- efficiency (typ.) (230 VAC): 95 %
- efficiency (typ.) (277 VAC): 95 %
- AC current: 7 A / 115 VAC 3.3 A / 230 VAC 2.9 A / 277VAC
- inrush current (typ.): cold start 70 A / 230 VAC
- leakage current: < 0.75 mA / 277 VAC
- protection:
- overcurrent (Note.4):
- 95 to 108 %
- protection type: constant current limiting, recovers automatically after fault condition is removed
- short-circuit: constant current limiting, recovers automatically after fault condition is removed
- overvoltage:
- 26 V to 30 V
- protection type: shut down o/p voltage, re-power on to recover
- overtemperature:
- protection type: shut down o/p voltage, re-power on to recover
- function:
- remote on/off control:
- power on: "Hi" > 2 - 5 V or (open circuit)
- power off: "Low" < 0 - 0.5 V or (short circuit)
- 5V standby: 5V SB : 5V@0.5A; tolerance +/-5%, ripple : 100mVp-p (max.)
- remote on/off control:
- environment:
- working temp.: -40 °C to +70 °C (refer to "derating curve")
- working humidity: 20 to 95 % RH non-condensing
- storage temp., humidity: -40 °C to +85 °C, 10 to 95 % RH
- temp. coefficient: ± 0.03 % / °C (0 °C to 60 °C)
- vibration: 10 to 500 Hz, 5 G 12 min. / 1 cycle, period for 72 min. each along X, Y, Z axes
- safety & EMC:
- safety standards (Note.7): UL8750, CSA C22.2 No. 250-13-12, EN61347-1, EN61347-2-13 independent; IP65 approved
- withstand voltage: I/P-O/P: 3.75K VAC I/P-FG: 2K VAC O/P-FG: 0.5K VAC
- isolation resistance: I/P-O/P, I/P-FG, O/P-FG: 100M ohms / 500 VDC / 25 °C / 70 % RH
- EMC emission: in compliance with EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (>50% load), EN6100-3-3
- EMC immunity: in compliance with EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
- others:
- MTBF: 76.9K hrs min. MIL-HDBK-217F (25 °C)
- dimensions: 280 x 144 x 48.5 mm
- overcurrent (Note.4):
Documents:On orderPrice (VAT included):