Test & Measurements
-
RS232 cable for HDxxx instruments ( Delta Ohm )
Vaata veel
-
Anemometer for measurement with Pitot-tubes, <br>SICRAM ( Delta Ohm )
Product code: HD2134P.0Description: • Micro-manometer - thermometer - anemometer for measurements with Pitot-tubes ; SICRAM module• Air speed: 3...180m/s ( hot-wire or vane probe, resolution: 0,1m/s ; accuracy: +-2% ) Temperature: -200...600°C ( with Pitot-tubes ) -200...1370°C ( K-type; resolution: 0,1 °C ; accuracy: +-0,1°C) Pressure: +-200 mbar ( diff.pressure; Max.load: +-1bar ; resolution: 0,01mbar ; accuracy: +-0,25% fs.) Volume : 0,01x10³ m³/h • Sensor accuracy:+- 0,02...0,6 m/s depends from probe • Power: 4 x 1,5V AA-batteries( lifetime ca' 200h) • Functions: MAX/MIN/AVG/REL/HOLD, automatic power off IP67 ; DIN45326 connectors Pa- mbar- mmH2O- PSI - m/s - km/h - mph - °C - m³/h - l/s• Includes: case, manual; witout probes & conn. cable ! ( HD2110CSNM needed for computer connection) ! • More information: HD2134P.0 Pitot-tubes K-type probesIn stock: FALSEPrice (VAT included):: 526.49 € -
Anemometer- thermometer ( Delta Ohm )
Product code: HD2103.1Description: • Thermo-anemometer , SICRAM• Air speed: 0...40m/s ( hot-wire or vane probe ) resloution: 0,01m/s ; 0,1°C ) accuracy:+- 0,02...0,6 m/s depends from probe Temperature: -30...110°C ( hot-wire, NTC; resolution: 0,1 °C ;accuracy: +-0,4°C -200...650°C ( Pt100, Pt1000 , Ni1000 ; resolution: 0,1 °C ; accuracy: +-0,1°C; • Power: 4 x 1,5V AA-batteries( lifetime ca' 200h)• RS232 , DeltaLog 9 software• Functions: MAX/MIN/AVG/REL/HOLD, automatic power off; IP67 ; DIN45326 m/s - km/h - mph - °C - m³/h - l/s• Includes: case, manual, ... without probes ! Computer cable needed : HD2110CSNM• More information: HD2103.1In stock: FALSEPrice (VAT included):: 444.51 € -
pH-conductivity-thermometer with RS232 ( Delta Ohm )
Product code: HD2156.1Description: • -2...20 pH ( resolution: 0,01 või 0,001 ; accuracy: +-0,001pH ) -1999...+1999 mV ( resolution: 0,1mV ; accuracy: +-0,1 mV ) -50...+200°C ( Pt100 / Pt1000 ) ; resolution: 0,1°C ; accuracy: +-0,25 °C ) 0...200 mS ( resolution: 0,1/1/10 µS ; accuracy: +-0,5%+-1nr. ) 4Ω...10 MΩ ( resolution: 0,1 /1/10/100/1k/1MΩ ; accuracy: +-0,5%+-1nr. ) 0...200g/l ( resolution: 0,5mg/l ..0,1g/l ; accuracy: +-0,5%+-1nr. ) 0...20g/l ( resolution: 1mg/l // 10g/l ; accuracy: +-0,5%+-1nr. )• Power: 4 x 1,5V AA-batteries( lifetime ca' 200h)• RS232 , DeltaLog 9 software• Functions: MAX/MIN/AVG/REL/HOLD, auto power off; IP67• Includes: case, manual; DeltaLog 9 software, * Probes ( pH, jconductivity, Pt100) & computer cable ( HD2110CSNM) must be ordered separately!More information: HD2156In stock: FALSEPrice (VAT included):: 518.81 € -
Photo-radiometer with RS232 ( Delta Ohm )
Product code: HD2102.1Description: • ILLUMINANCE, LUMINANCE, PAR, IRRADIANCE , Integral Q(t), UVA, UVB, UVC, ERY ; SICRAM• 0,1...199990 Lux ; klass C ( ILLUMINANCE ; CIE n.69-UNI 11142) suitable probe: LP471PHOT 0,1...1999900 Cd/m² ; klass C ( LUMINANCE ; Nurk: 2° ; CIE n.69-UNI 11142) - suitable probe: LP471LUM2 0,01...10000 µmol/m²s ( PAR ; 400..700 nm ) - suitable probe: LP471PAR 0,0001...2000 W/m² ( IRRADIANCE ; 400..1050 nm ) - suitable probe: LP471RAD 0,0001...2000 W/m² ( IRRADIANCE UVA ; 315..400 nm) - suitable probe: LP471UVA 0,0001...2000 W/m² ( IRRADIANCE UVB ; 280..315 nm) - suitable probe: LP471UVB 0,0001...2000 W/m² ( IRRADIANCE UVC ; 220..280 nm) - suitable probe: LP471UVC 0,0001...2000 W/m² ( IRRADIANCE UV Erythema ; 250..400 nm; CEI EN60335-2-27)- suitable probe: LP471ERY• Power: 4 x 1,5V AA-batteries( lifetime ca' 200h)• RS232 , DeltaLog 9 software• Functions: MAX/MIN/AVG/REL/HOLD, Automatic power-off; IP67 ; DIN45326• Includes: case, manual * Probes( LP471) & computer cable: HD2110CSNM must be ordered separately !!!• More information: HD2102In stock: FALSEPrice (VAT included):: 532.90 € -
Thermo-hygrometer, RS232 ( Delta Ohm )
Product code: HD2101.1Description: • 0...100% RH; -200...+650°C( Pt100 /1000)• resolution: 0,1%RH; 0,1°C• instrument accuracy: +-0,1%RH; +-0,1°C• Probes: Pt100 / Pt1000 / Ni1000 or combinated thermo-hygro probe with SICRAM• Response time:humidity: 10s• Power: 4 x 1,5V AA-batteries( lifetime: 200h )• RS232; DeltaLog 9 software• Functions: MAX / MIN / AVG / REL / HOLD, dewpoint, auto power off ; IP67• Includes: manual, batteries, case, DeltaLog 9 software, * Probes with SICRAM & PC-cable( CS2110CSNM) must be ordered separately !!!• More inforamtion:HD2101In stock: FALSEPrice (VAT included):: 365.09 € -
pH-thermometer with RS232 ( Delta Ohm )
Product code: HD2105.1Description: • -2...20 pH ( resolution: 0,01 või 0,001 ; accuracy: +-0,001pH )-1999...+1999 mV ( resolution: 0,1mV ; accuracy: +-0,1 mV ) -200...+650°C ( Pt100 / Pt1000 / Ni1000) ; resolution: 0,1°C ; accuracy: +-0,1 °C )• Power: 4 x 1,5V AA-batteries( lifetime ca' 200h)• RS232 DeltaLog 9 software• Functions : MAX/MIN/AVG/REL/HOLD, auto power-off; IP67• Includes: case, manual; DeltaLog 9 software, * Probes & PC-cable( HD2110CSNM ) must be ordered separately !!!• More information: HD2105In stock: FALSEPrice (VAT included):: 376.61 €