Test & Measurements

Print

 

  • DIGITAL CLAMP METER - CAT III - 600 V - AC/DC - NCV - with data-hold function

    Product code:

    DCM140

    Description:

    Features:
    1. LCD display with automatic polarity indication
    2. data-hold function
    3. AC and DC voltage measurements up to max. 600 V
    4. AC current measurement up to max. 600 A
    5. DC current measurements up to max. 600 A
    6. max. Ø for conductor: 23 mm
    7. resistance measurements: max. 40 Mohm
    8. diode test, continuity test & backlight
    9. safety: indoor use only (overvoltage Cat. III 600 V)
    10. non contact voltage detect (NCV)
    11. led flashlight
    12. temperature measurements: -20°C - 1.000°C
    13. frequency measurements: mac. 10 MHz
    14. duty cycle measurements: 0.5 - 99 % @ pulse width of 100 µs to 100 ms
    15. capacitance measurement: max. 100 mF
    16. Important safety information
    Specifications:
    1. DC voltage: 0.4 / 4 / 40 / 400 / 600 V
      1. basic accuracy: ± (0.5% of rdg + 3 digits) for 0.4 V range / ± (0.8% of rdg + 5 digits) for 4 V ~ 400 V range / ± (1.0% of rdg + 5 digits) for 600 V range
      2. input impedance: 10 Mohm
      3. maximum input: 600 V
    2. AC voltage: 0.4 / 4 / 40 / 400 / 600 V
      1. basic accuracy: ± (1.0% of rdg + 10 digits) for 0.4 V range / ± (1.0% of rdg + 5 digits) for 4 V ~ 400 V range / ± (1.2% of rdg + 5 digits) for 600 V range
      2. input impedance: 10 Mohm
      3. frequency range: 50 - 1000 Hz
      4. maximum input: 600 V
    3. DC current: 40 / 400 / 600 A (max. line voltage 240 V)
      1. basic accuracy: ± (2.5% of rdg + 10 digits) for 40 A ~ 600 A range
      2. overload protection: -
    4. AC current: 40 / 400 / 600 A (max. line voltage 240 V)
      1. basic accuracy: ± (2.5% of rdg + 10 digits) for 40 A ~ 600 A range
      2. overload protection: -
    5. resistance: 400 / 4 K / 40 K / 400 K / 4 M / 40 M
      1. basic accuracy: ± (1.0% of rdg + 10 digits) for 400 ohm range / ± (0.8% of rdg + 5 digits) for 4 K ~ 4 M range / ± (2.0% of rdg + 10 digits) for 40 M range
      2. overload protection: 15 s max. 250 V (all ranges)
    6. capacitance: 10 n / 100 n / 1 µ / 10 µ / 100 µ / 1 m / 10 m / 100 mF
      1. accuracy: ± (4.0% of rdg + 25 digits) for 10 nF range / ± (4.0% of rdg + 15 digits) for 100 nF ~ 100 µF range / ± (5.0% of rdg + 25 digits) for 1 mF ~ 100 mF range
      2. overload protection: 15 s max. 250 V (all ranges)
    7. inductance: -
      1. accuracy: -
    8. frequency: 10 Hz / 100 Hz / 1 KHz / 10 KHz / 100 KHz / 1 MHz / 10 MHz
      1. basic accuracy: ± (0.5% of rdg + 2 digits) for 10 Hz ~ 10 MHz range
      2. overload protection: 15 s max. 250 V (all ranges)
    9. temperature: -20°C - 1000°C
      1. basic accuracy: ± (5% of rdg + 4°C) for -20°C ~ 0°C range / ± (2% of rdg + 3°C) for 0°C ~ 400°C range / ± (3% of rdg + 3°C) for 400°C ~ 1000°C range
      2. overload protection: 15 s max. 250 V
    10. overrange: yes "OL"
    11. continuity buzzer: yes
    12. transistor test: -
    13. diode test: yes
    14. low-battery indication: yes
    15. maximum display: 3999
    16. LCD display size: 24 x 37 mm
    17. ranging mode: auto/manual
    18. data hold: yes
    19. backlight: yes
    20. dimensions: 194 x 72 x 35 mm
    21. weight: 230 g
    22. power supply: 3 x 1.5 V AAA LR03 battery (incl.)
    23. packaging: box
    24. accessories: manual / test leads / thermocouple / battery / carrying case
    25. auto power-off: yes
    Documents:
    On order

    Price (VAT included):