Latest products

Print

  • DIGITAL MULTIMETER - CAT III 600 V / CAT IV 300 V - 1999 COUNTS

    Product code:

    DVM895

    Description:

    Features:
    1. CAT III 600V / CAT IV 300 V
    2. automatic polarity indication
    3. automatic zero adjustment
    4. voltage measurements: 600 VAC and 600 VDC max.
    5. current measurements: DC 15 A and AC 15 A max.
    6. resistance measurements: 200 MOhm max.
    7. capacitance measurements: 200 µF max.
    8. K-type thermocouple measurements: -50°C to 800°C
    9. frequency measurements: 20 kHz
    10. with separate test leads (incl.): TLM72
    11. pollution degree 2
    12. [link url=http://www.velleman.eu/downloads/1/multimeter_overvoltage_installation_categories.pdf]Important safety information[/link]
    Specifications:
    1. DC voltage: 0-200 mV / 2 V / 20 V / 200 V / 600 V
      1. basic accuracy: ± (0.5% rdg + 2 digits) , ±(0.8% rdg + 2 digits) for 600 V range
      2. input impedance: 10 MOhm
      3. maximum input: 600 V
      4. overload protection: 600 V DC or AC rms
    2. AC voltage: 0-2 V / 20 V / 200 V / 600 V
      1. basic accuracy: ± (0.8% rdg + 3 digits) , ± (1.2% rdg + 3 digits) for 600 V range
      2. input impedance: 1 MOhm for 2 V range, 10 MOhm for other ranges
      3. frequency range: 40-500 Hz
      4. maximum input: 600V DC or AC rms
    3. DC current: 200 µA / 2 mA / 20 mA / 200 mA / 15 A
      1. basic accuracy: ± (1.2% rdg + 2 digits), ± (1.5% rdg + 2 digits) for 200mA range, ± (2.0% rdg + 3 digits) for 15 A range
      2. overload protection: 500 mA / 600 V, 15 A / 600 V fuse
    4. AC current: 2 mA / 20 mA / 200 mA / 15 A
      1. basic accuracy: ± (1.5% rdg + 3 digits), ± (2.0% rdg + 3 digits) for 200mA range, ± (2.5% rdg + 5 digits) for 15 A range
      2. overload protection: 500 mA / 600 V, 15 A / 600 V fuse
      3. frequency range: 40-500 Hz
    5. resistance: 0-200 Ohm / 2 kOhm / 20 kOhm / 200 kOhm /2 MOhm / 20 MOhm / 200 MOhm
      1. basic accuracy: ± ( 1.0% rdg +3 digits) for 200 Ohm range, ± (1.0% rdg + 2 digits) for 2 KOhm to 2 Mohm range, ± (1.5% rdg + 3 digits) for 20 MOhm range, ± (5.0% rdg + 5 digits) for 200 MOhm range
      2. overload protection: 600 VDC or AC rms
    6. capacitance: 2000 pF / 20 nF / 200 nF / 2 µF / 200 µF
      1. basic accuracy: ± (2.5% rdg + 10 digits) for 2000 pF range, ± (2.5% rdg + 5 digits) for 20nF to 20 µF range, ± (5.0% rdg + 10 digits) for 200 µF range
      2. overload protection: 500 mA / 600 V fuse
    7. temperature: -50-150°C / 150-800°C
      1. basic accuracy: ± (3°C + 3 digits) for -50-150°C range, ± (3% + 3 digits) for 150-800°C range
      2. overload protection: 500 mA / 600V fuse
      3. NiCr-NiSi sensor
    8. frequency : 20 kHz
      1. basic accuracy: ± (2.0% rdg + 5 digits)
      2. overload protection: 600 VDC or AC rms
      3. sensitivity: sine wave 0.5 V rms
    9. battery test: no
    10. audible continuity measurement: built-in buzzer sounds if resistance is less than 50 Ohm
      1. test voltage: approx. 3 V
    11. diode measurement: test forward voltage of diode
      1. test voltage: approx. 3 V (reversed DC voltage)
    12. overrange: yes
    13. continuity buzzer: yes
    14. diode test: yes
    15. low-battery indication: yes
    16. maximum display: 3 1/2
    17. LCD display:
      1. size: 62 x 36 mm
      2. digits: max. 1999
    18. ranging mode: manual
    19. data hold: yes
    20. backlight: yes
    21. dimensions: 190 x 100 x 40 mm
    22. weight (with battery): 300 g
    23. power supply: 9V 6F22 (incl.)
    24. auto power-off: yes
    25. operating environment:
      1. temperature: 0 °C to 40 °C (32 to 104 °F)
      2. humidity: < 80% RH.
    26. storage environment:
      1. temperature: -20 °C to 60 °C (-4 to 140 °F)
      2. humidity: < 90% RH
    27. fuse:
      1. F0.5 A / 600 V 5 x 20 mm
      2. F15A / 600 V 5 x 20 mm
    28. test lead probe : CAT III 1000 V / CAT IV 600 V, 15 A, L = 75 cm
    29. IP rating: IP20
    Documents:
    Yes

    Price (VAT included):

    67.65 €